Universal Logic Analyzer - UniLogic
User manual


Copyright © 1997-2002 CnCLab


All rights reserved.

NOTE: The program is delivered "AS IS". The author does not carry any responsibility for possible loss of the data, breakage   of the equipment, inoperability of the program on your computer and other extreme situations, directly or indirectly occurred at use by you of this program. However, from the party, the author applies a maximum of efforts to not allow similar situations and addresses to the users with the request to inform slightest mistakes or discrepancies connected to functioning or the description of the given program.

INTRODUCTION

    Welcome in UniLogic - hardware-software system, which will allow to replace the multichannel logic analyzer, generator of digital   sequences and freqmeter personal by the computer. For work UniLogic on your computer in the minimal variant it is
required to collect only elementary adapter on LPT port.

1. Requirement to configuration of computer

UniLogic normally functions in the following conditions:

  • Computer IBM PC/AT or compatible;
  • Processor 386 and higher;
  • VGA-compatible videoadapter;
  • mouse;
  • MS-DOS 5.0 or later versions;
  • 640Kb of the Basic RAM;
  • As a minimum 300KB on a hard disk

    The additional recommendations: PROCESSOR: 486 And HIGHER; < CD-ROM;

2. Features

  • Viewing logic signals in a real time scale
  • Storing of logic signals with an opportunity of the subsequent viewing and record in a file.
  • Decoding saved signals of consecutive protocols I2C, Microwire and others (Only in full version)
  • Play of recorded signals (Only in full version)
  • Freqmeter
  • the Maximal number of channels - 4 (8)
  • Ranges of input signals 0... 5 In (TTL)
  • Size of the buffer - 64 Kb
  • Adjustment of frequency of display.

Maximal working frequency is determined by PC speed and makes 300... 1000 kHz. Really it is possible to work signals by
frequency above half of record frequency. (to find out this frequency for your computer open the Information item of the menu. The start under EMM/QEMM, WIN95 can significant lower working frequency.

3. Work with program


The management is carried out only by mouse. An exit from
modes "O-scope", "Record", "Freqmeter" - right button of the mouse.
The user interface - english/russian.

4. Decoders

Connect adapter channels:

Channels:

A

B

C

D

I2C,24cXX:

SCL

SDA

- -

SDA2506:

C D CE -

93Cxx,CXK101X:

CS

CLK

DI

DO

S2100:

CS

CLK

DO

RST